  datasheet power line filter for shielded rooms & secure area 250/277/480 v, 50/60 hz, 1--100 a, 40 c ordering code: b84299d6***a(b)00* date: 2011--07--22 version: 06 page 1 of 10 ? epcos ag 2011. reproduction, publication and disseminatio n of this publication, enclosures hereto and the information contained therein without epcos prior express consent is prohibited.
power line filter b84299d6***a(b)00* for shielded rooms & secure area technical data and measuring conditions rated frequency f r 50/60 hz rated temperature t r 40 c overload capability (thermal) for 3 min per hour or for 30 s per hour 1.5 x i r 2.5 x i r climatic category (iec 60068--1) 25/85/21 rated frequency f r 50/60 hz b84299d60*0b003 -- rated voltage ur 250 v ac test voltage line to line for 2 s u test 1768 v dc test voltage line to case for 2 s u test 2121 v dc B84299D6300B000 -- rated voltage ur 250 v ac test voltage line to line for 2 s u test 1768 v dc test voltage line to case for 2 s u test 2121 v dc b84299d6*00b003 -- rated voltage ur 480 v ac test voltage line to line for 2 s u test 2158 v dc test voltage line to case for 2 s u test 2200 v dc b84299d6101a003 -- rated voltage ur 277 v ac test voltage line to line for 2 s u test 2158 v dc test voltage line to case for 2 s u test 2200 v dc characteristics and ordering codes i r line terminals: threaded studs load terminals: cabels i leak 2) r typ approx. weight ordering code approvals for usa, canada: ul (listed) cul (listed) a ma m  kg 1 #6--32 unc 2a awg 18 1.6 107 1.9 b84299d6010b003 x 5 #6--32 unc 2a awg 18 1.6 107 1.9 b84299d6050b003 x 30 m6 awg 12 157 3.2 1.5 B84299D6300B000 x 30 m6 awg 10 1706 7.7 10.8 b84299d6300b003 x 60 m8 awg 6 1714 6 22 b84299d6600b003 x 100 m10 awg 2 3751 3 11.5 b84299d6101a003 x 2) calculation according draft proposal iec 60939--1 ed. 3 ( 2008--10--29), annex a, calculation of leakage current a t 50hz. 3) x = approval granted p = pending d = design complies with -- = none please read cautions and warnings and important notes at the end of this document. page 2 of 10 b84299--d6*--a(b)*--06--7659
power line filter b84299d6***a(b)00* for shielded rooms & secure area circuit diagram for b84299d6010b003 and b84299d6050b003 load line l l n n circuit diagram for B84299D6300B000 line l o a d l n l n circuit diagram for b84299d6300b003 line load l1 l1 l2 l2 please read cautions and warnings and important notes at the end of this document. page 3 of 10 b84299--d6*--a(b)*--06--7659
power line filter b84299d6***a(b)00* for shielded rooms & secure area circuit diagram for b84299d6600b003 line load l1 l1 l2 l2 circuit diagram for b84299d6101a003 l i n e l l l o a d please read cautions and warnings and important notes at the end of this document. page 4 of 10 b84299--d6*--a(b)*--06--7659
power line filter b84299d6***a(b)00* for shielded rooms & secure area dimensions for b84299d6010b003, b84299d6050b003 all dimensions are in mm. 25 230 15 63 30 20.6 79 24 20 60 #0.1 m4 39.8 20 #5 +10 30 +10 450 m25x1,5 10 3x litze/ litz wire awg18 beschriftung 89 please read cautions and warnings and important notes at the end of this document. page 5 of 10 b84299--d6*--a(b)*--06--7659
power line filter b84299d6***a(b)00* for shielded rooms & secure area dimensions for B84299D6300B000 all dimensions are in mm. please read cautions and warnings and important notes at the end of this document. page 6 of 10 b84299--d6*--a(b)*--06--7659
power line filter b84299d6***a(b)00* for shielded rooms & secure area dimensions for b84299d6300b003 all dimensions are in mm. please read cautions and warnings and important notes at the end of this document. page 7 of 10 b84299--d6*--a(b)*--06--7659
power line filter b84299d6***a(b)00* for shielded rooms & secure area dimensions for b84299d6600b003 all dimensions are in mm. please read cautions and warnings and important notes at the end of this document. page 8 of 10 b84299--d6*--a(b)*--06--7659
power line filter b84299d6***a(b)00* for shielded rooms & secure area dimensions for b84299d6101a003 all dimensions are in mm. please read cautions and warnings and important notes at the end of this document. page 9 of 10 b84299--d6*--a(b)*--06--7659
power line filter b84299d6***a(b)00* for shielded rooms & secure area cautions and warnings  please note the advices in our data book emc filters (lates t edition); attention should be paid to the chapter general safety notes.  it shall be ensured that only qualified persons (electricit y specialists) are engaged on work such as planning, assembl y, installation, opera- tion, repair and maintenance. they must be provided with the corresponding documentation.  danger of electric shock. emc filters contain components th at store an electric charge. dangerous voltages can continu e to exist at the filter terminals for longer than five minutes even after the power has been switched off.  the protective earth connections shall be the first to be mad e when the emc filter is installed and the last to be disconnec ted. depending on the magnitude of the leakage currents, the particular spe cifications for making the protective--earth connection m ust be observed.  impermissible overloading of the emc filter, such as with ci rcuits able to cause resonances, impermissible voltages at higher frequencies etc. can lead to bodily injury and death as well as cause subst antial material damages (e.g. destruction of the filter hou sing).  emc filters must be protected in the application against imp ermissible exceeding of the rated currents by overcurrent p rotective.  in case of leakage currents > 3.5 ma you shall mount the pe cond uctor stationary with the required cross section before beg inning of op- eration and save it against disconnecting. for leakage curr ents i l 4) < 10 ma the pe conductor must have a ku value 3) of 4.5; for leakage currents i l  10 ma the pe conductor must have a ku value of 6. 3) the ku value (symbol ku) is a classification parameter of s afety--referred failure types designed to ensure protecti on against hazardous body currents and excessive heating. a value of ku = 4.5 with respect to interruptions is attained: -- with a permanently connected protective earth circuit 1.5 mm 2 -- with a protective earth circuit 2.5 mm 2 connected via shroud connectors (iec 60309--2). ku = 6 with respect to interruptions is achieved for fixed--c onnection lines 10 mm 2 where the type of connection and line layout correspond to th e requirements for pen conduc- tors as specified in relevant standards. 4) i l = leakage current let--go important notes the following applies to all products named in this publicat ion: 1. some parts of this publication contain statements about the suitability of our products for certai n areas of application . these statements are based on our knowledge of typical requirements that are o ften placed on our products in the areas of application conce rned. we neverthe- less expressly point out that such statements cannot be regarded as binding statemen ts about the suitability of our products for a particular customer application . as a rule, epcos is either unfamiliar with individual custo mer applications or less familiar with them than the customers themselves. for these reasons, it is always ul timately incumbent on the customer to check and decide wheth er an epcos product with the properties described in the product specif ication is suitable for use in a particular customer applica tion. 2. we also point out that in individual cases, a malfunction of electronic component s or failure before the end of their usual service life cannot be completely ruled out in the current state of the art , even if they are operated as specified . in customer applications requiring a very high level of operational safety and especially in cus tomer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident preven tion or life--saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by t he customer (e.g. installation of protective circuitry or r edundancy) that no injury or damage is sustained by third parties in the event of malfun ction or failure of an electronic component. 3. the warnings, cautions and product--specific notes must be observed . 4. in order to satisfy certain technical requirements, some of the products described in this publication may conta in substances subject to restrictions in certain jurisdictions (e.g. because the y are classed as hazardous) . useful information on this will be found in our material data sheets on the internet (www.epcos.com/material). sho uld you have any more detailed questions, please contact our sales offices. 5. we constantly strive to improve our products. consequent ly, the products described in this publication may change from t ime to time . the same is true of the corresponding product specification s. please check therefore to what extent product descriptio ns and specifications contained in this publication are still applicable before o r when you place an order. we also reserve the right to discontinue production and delivery of products . consequently, we cannot guarantee that all products named in this publication will always be available. the afor ementioned does not apply in the case of individual agreemen ts deviating from the foregoing for customer--specific products. 6. unless otherwise agreed in individual contracts, all orders subject to the current version of the general ter ms of delivery for products and services in the electrical industry published by the th e german electrical and electronics industry association ( zvei) . 7. the trade names epcos, baoke, alu--x, ceradiode, csmp, cs sp, ctvs, deltacap, digisimic, dssp, formfit, miniblue, mi nicell, mkd, mkk, mlsc, motorcap, pcc, phasecap, phasecube, phasemod, p hicap, siferrit, sifi, sikorel, silvercap, simdad, simic, simid, sineformer, siov, sip5d, sip5k, thermofuse, windcap are trademarks registered or pending in europe and in other countries. further information will be found on the internet at www.epcos.com/ trademarks. 1 please read cautions and warnings and important notes at the end of this document. page 10 of 10 b84299--d6*--a(b)*--06--7659


▲Up To Search▲   

 
Price & Availability of B84299D6300B000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X